Product Details
Double-ended shear beam
Â
FEATURES:
â—Capacity: 5-50t
â—Steel ball loading, strong restoration ability
â—Easy complete installation, high weighing accuracy
â—OIML C3 certificate
â—Alloy Steel, stainless steel
Â
APPLICATION:
â—Truck scale
â—Railway scale
â—Blending scale and all kinds of weighing apparatus
Â
Â
Outline Dimension
|
Rated capacity(t)
|
L
|
L1
|
L2
|
L3
|
W
|
W1
|
W2
|
H
|
H1
|
H2
|
C1
|
C2
|
C3
|
C4
|
5
|
224
|
125
|
80
|
45
|
135
|
100
|
10
|
168.8
|
11
|
20
|
Φ68
|
Φ30
|
Φ18
|
Φ50.8
|
10ã€15ã€20ã€25ã€30
|
240
|
125
|
80
|
45
|
135
|
100
|
10
|
223.5
|
11
|
20
|
Φ85~88
|
Φ30
|
Φ18
|
Φ75
|
40
|
240
|
125
|
80
|
45
|
135
|
100
|
10
|
239.5
|
11
|
20
|
Φ88
|
Φ30
|
Φ18
|
Φ75
|
50
|
340
|
160
|
124
|
45
|
160
|
124
|
10
|
260
|
11
|
20
|
Φ98
|
Φ40
|
Φ22
|
Φ75
|
Â
SPECIFICATION
Rated capacity: 5- 50t
Rated output:2.0±0.002mv/v
Combined error: ±0.03% F.S
Non-repeatability: ±0.02% F.S
Non-linearity: ±0.02% F.S
Hysteresis error: ±0.02% F.S
Zero balance: ±1% F.S
Creep error(30minutes): ±0.02% F.S
Temperature effect on zero: ±0.02% F.S
Temperature effect on output: ±0.02% F.S
Compensated temperature range: -10 ~ +40℃
Operating temperature range: -30 ~ +70℃
Maximum safe overload: 150% OF R.C
Ultimate safe overload: 200% OF R.C
Recommended Excitation: 10 ~ 12V DC
Maximum Excitation: 15V DC
Environment protection: IP68
Input impedance: 750±10Ω
Output impedance: 702±3Ω; 703±5Ω(cable≥15m);
Insulation resistance at 50V DC: ≥5000MΩ
Material: alloy steel, stainless steel
Cable : length 5.2m(5t), 8m(10t), 10meter(15t), 10/12m(20t),12/16m(25-50t); diameter 6mm